D40-TDI
Technical Design & Implementation
Implementation: turn a verified programme into coordinated interior construction that can be priced, built and checked. Modules 001–012 are loaded as draft lessons for study.
Competency outcome: Analyse applicable requirements and produce coordinated technical design solutions and documentation.
D40 Academy is an independent professional education and training initiative of Design Forty. It is not affiliated with, endorsed by, or accredited by CIDQ, ICC or other referenced organizations unless expressly stated. Completion of a D40 Academy programme does not confer NCIDQ certification, professional licensure or statutory registration.
TDI-001 · Module 01
Existing Conditions and Site Analysis
Record what is already built before proposing a change.
Produce a conditions record a design can be checked against.
- 01 Existing Conditions in Technical Design: From Programming Survey to Verified Base PlanFull sample · 75 minpublished
- 02 Survey Planning, Instruments and AccuracyFull sample · 75 minpublished
- 03 Measuring, Recording and Producing the Verified Base DrawingsFull sample · 75 minpublished
- 04 Base-Building Records, Building Standards and the Work LetterFull sample · 75 minpublished
- 05 Structural Constraints: Columns, Slabs, Penetrations and MovementFull sample · 80 minpublished
- 06 Vertical Dimensions and the Ceiling ZoneFull sample · 80 minpublished
- 07 Base-Building Services and Fire Protection SurveyFull sample · 80 minpublished
- 08 Surveying Existing Egress and Life-Safety ElementsFull sample · 80 minpublished
- 09 Surveying Existing Accessibility ConditionsFull sample · 80 minpublished
- 10 Hazardous Materials and Environmental Condition ScreeningFull sample · 75 minpublished
- 11 Building and Site Context Analysis for an Interior Fit-OutFull sample · 75 minpublished
- 12 Capstone: SMF Existing Conditions Report and Verified Base PlanFull sample · 90 minpublished
TDI-002 · Module 02
Occupancy Classification and Code Analysis
Classify use from the adopted regulation and trace what that classification changes.
Prepare a code analysis that names its edition and its jurisdiction.
- 01 From Preliminary Code Review to a Formal Code AnalysisFull sample · 75 minpublished
- 02 Field-Verified Areas: Gross, Net and Occupiable Floor SpaceFull sample · 75 minpublished
- 03 Occupancy Classification of SMF's SpacesFull sample · 80 minpublished
- 04 Formal Occupant Load CalculationFull sample · 85 minpublished
- 05 Cumulative Occupant Loads and Intervening SpacesFull sample · 80 minpublished
- 06 Mixed Occupancy: Accessory, Nonseparated and Separated OptionsFull sample · 85 minpublished
- 07 Incidental Uses in the SMF Fit-OutFull sample · 75 minpublished
- 08 Construction Type, High-Rise Provisions and Building FeaturesFull sample · 80 minpublished
- 09 Rated Elements in an Interior Fit-OutFull sample · 80 minpublished
- 10 Interior Finish Classification and Decorative MaterialsFull sample · 75 minpublished
- 11 Plumbing Fixture Calculations for the SMF TenancyFull sample · 80 minpublished
- 12 Capstone: SMF Formal Code Matrix and the Town Hall DecisionFull sample · 90 minpublished
TDI-003 · Module 03
Means of Egress and Life Safety
Keep the way out clear, sized and understandable for the people who will need it.
Trace an exit path and list the assumptions behind it.
- 01 Mapping SMF's Means of Egress SystemFull sample · 75 minpublished
- 02 Number of Exits from Spaces and StoriesFull sample · 80 minpublished
- 03 Common Path of Egress TravelFull sample · 80 minpublished
- 04 Exit Access Travel DistanceFull sample · 80 minpublished
- 05 Exit and Exit Access Doorway SeparationFull sample · 80 minpublished
- 06 Egress Capacity and Width: Stairs and DoorsFull sample · 85 minpublished
- 07 Corridors, Aisles and Dead EndsFull sample · 75 minpublished
- 08 Egress Doors: Size, Swing, Landings and AccessibilityFull sample · 80 minpublished
- 09 Door Hardware, Locking and Security on the Egress PathFull sample · 80 minpublished
- 10 Exit Stairways: Geometry, Handrails, Guards and EnclosuresFull sample · 80 minpublished
- 11 Accessible Means of Egress, Egress Lighting and Exit SignsFull sample · 80 minpublished
- 12 Capstone: SMF Life-Safety and Egress PlanFull sample · 85 minpublished
TDI-004 · Module 04
Applied Accessibility
Apply accessible clearances to doors, routes, sanitary rooms and work areas on a real plan.
Mark a plan with the access decisions and the standard they were checked against.
- 01 Scoping Accessibility for the SMF AlterationFull sample · 75 minpublished
- 02 Dimensioning Accessible Routes Through the SMF FloorsFull sample · 80 minpublished
- 03 Turning Space, Clear Floor Space and Knee and Toe ClearanceFull sample · 80 minpublished
- 04 Accessible Doors: Maneuvering Clearances and Door DetailsFull sample · 80 minpublished
- 05 Single-User Accessible Toilet Rooms: Layout and DimensioningFull sample · 80 minpublished
- 06 Grab Bars, Accessories and Blocking in Accessible ToiletsFull sample · 75 minpublished
- 07 Lavatories, Sinks, Pantry and Work SurfacesFull sample · 75 minpublished
- 08 Multi-User Toilet Rooms, Compartments and Wellness ShowersFull sample · 80 minpublished
- 09 Ramps and Level Changes: The Town Hall PlatformFull sample · 80 minpublished
- 10 Reach Ranges, Operable Parts, Protruding Objects and CountersFull sample · 75 minpublished
- 11 Tactile Signage, Assembly Seating and Assistive ListeningFull sample · 75 minpublished
- 12 Capstone: SMF Accessibility Plans and Toilet Room PackageFull sample · 90 minpublished
TDI-005 · Module 05
Advanced Space Planning
Plan a workplace that can change without abandoning the programme.
Test a plan for both today's headcount and a stated future change.
- 01 From Blocking to an Engineered Plan: Grids, Modules and Floor-Plate DepthFull sample · 75 minpublished
- 02 Multi-Zone Workplace Planning and Two-Floor StackingFull sample · 80 minpublished
- 03 Workstations and Work Settings: Dimensioning the NeighbourhoodsFull sample · 80 minpublished
- 04 Circulation Engineering: Hierarchy, Widths and Accessible AislesFull sample · 80 minpublished
- 05 Testing Layouts: Capacity, Encroachment, Dead Ends and Two-Exit RoomsFull sample · 80 minpublished
- 06 Reconfigurable Layouts: Universal Plans, Demountable Walls and Service FlexibilityFull sample · 75 minpublished
- 07 Enclosed Room Suites: Meeting Rooms, Boardroom, Focus Rooms and Acoustic ZoningFull sample · 80 minpublished
- 08 Town Hall Configurations: Occupant Loads, Exits, Seating Layouts and Chair StorageFull sample · 80 minpublished
- 09 Support Spaces and Services: Pantries, Wet Areas, Storage, File Rooms and CommsFull sample · 75 minpublished
- 10 Wayfinding and Orientation in a Ring-Corridor PlanFull sample · 75 minpublished
- 11 Test-Fit Metrics: Net, Occupant Area, Efficiency, Density and Sharing RatiosFull sample · 80 minpublished
- 12 Capstone: SMF Space Plan Package for Levels 7 and 8Full sample · 90 minpublished
TDI-006 · Module 06
Interior Construction and Partitions
Select partition types for fire, acoustic and structural roles.
Specify a partition by its performance, not only by its thickness.
- 01 Partition Types and the Partition Schedule for SMFFull sample · 75 minpublished
- 02 Steel Stud Framing: Sizes, Spacing, Heights and Deflection CriteriaFull sample · 80 minpublished
- 03 Gypsum Board Systems: Types, Layers, Trims and Finish LevelsFull sample · 75 minpublished
- 04 Head-of-Wall Deflection, Slip Joints and Building MovementFull sample · 80 minpublished
- 05 Fire Barriers and Fire Partitions: Ratings, Continuity and SMF ApplicationsFull sample · 80 minpublished
- 06 Smoke Barriers, Smoke Partitions and Smoke-Resisting EnclosuresFull sample · 75 minpublished
- 07 Shaft Walls and the Core InterfaceFull sample · 75 minpublished
- 08 Penetrations and Firestopping in Rated Partitions and SlabsFull sample · 80 minpublished
- 09 Openings in Rated Walls: Fire Doors, Frames, Hardware and Fire-Rated GlazingFull sample · 80 minpublished
- 10 Acoustic Partitions: STC Targets, Construction Methods, Flanking and DoorsFull sample · 80 minpublished
- 11 Glazed, Demountable and Specialty Partitions: Safety Glazing, Rated Glass and Seismic BracingFull sample · 75 minpublished
- 12 Capstone: SMF Partition and Interior Construction PackageFull sample · 90 minpublished
TDI-007 · Module 07
Doors, Windows and Glazing
Coordinate doors and glazing with egress, access, privacy and safety glass decisions.
Schedule openings with the performance each one has to meet.
- 01 The Door Opening as a System: Types, Leaves and SizesFull sample · 70 minpublished
- 02 Door Frames: Hollow Metal, Wood and AluminiumFull sample · 70 minpublished
- 03 Door Hardware I: Hinges, Pivots and LocksetsFull sample · 75 minpublished
- 04 Door Hardware II: Closers, Panic Hardware, Stops, Seals and ThresholdsFull sample · 75 minpublished
- 05 Door, Frame and Hardware SchedulesFull sample · 70 minpublished
- 06 Fire-Rated Door Assemblies: Ratings, Labels and Smoke ControlFull sample · 80 minpublished
- 07 Fire-Rated Glazing: Fire-Protection versus Fire-ResistanceFull sample · 80 minpublished
- 08 Safety Glazing and Hazardous LocationsFull sample · 80 minpublished
- 09 Glass Partitions, Frameless Doors and SidelightsFull sample · 75 minpublished
- 10 Acoustic Doors and Glazing for Speech PrivacyFull sample · 75 minpublished
- 11 Switchable Glazing, Window Coverings and the Curtain-Wall InterfaceFull sample · 70 minpublished
- 12 Openings Coordination and Submittal Review (Capstone)Full sample · 90 minpublished
TDI-008 · Module 08
Ceilings and Building Services Coordination
Fit ceiling height, light, air and structure into one section.
Find a clash between a ceiling and a service before it reaches site.
- 01 Ceiling Systems and the Plenum: What the Ceiling Has to DoFull sample · 70 minpublished
- 02 Suspended Acoustical Ceilings and the Planning ModuleFull sample · 75 minpublished
- 03 Gypsum Board Ceilings, Bulkheads and AccessFull sample · 75 minpublished
- 04 The Reflected Ceiling Plan: Content and CoordinationFull sample · 75 minpublished
- 05 Plenum Depth: Layering Structure, Ducts, Pipes, Lights and CeilingFull sample · 80 minpublished
- 06 HVAC Coordination and Return-Air PlenumsFull sample · 75 minpublished
- 07 Sprinkler Coordination in the CeilingFull sample · 75 minpublished
- 08 Lighting Integration with the CeilingFull sample · 75 minpublished
- 09 Ceiling Acoustics: NRC, SRA, CAC and Speech PrivacyFull sample · 75 minpublished
- 10 Seismic Restraint of Suspended CeilingsFull sample · 80 minpublished
- 11 Ceiling Code Checks: Heights, Headroom, Finishes and Rated CeilingsFull sample · 75 minpublished
- 12 Integrated Ceiling Coordination (Capstone)Full sample · 90 minpublished
TDI-009 · Module 09
Millwork and Construction Detailing
Draw joinery so it can be built, reached and maintained.
Detail a typical workstation or counter with its assumptions labelled.
- 01 Architectural Woodwork, Finish Carpentry and Quality GradesFull sample · 70 minpublished
- 02 Lumber and Veneer Cuts, Flitches and MatchingFull sample · 75 minpublished
- 03 Panel Products, Substrates and High-Pressure LaminatesFull sample · 75 minpublished
- 04 Casework Construction, Door and Drawer FrontsFull sample · 75 minpublished
- 05 Installation: Blocking, Scribes, Field Measurement and Site ConditionsFull sample · 70 minpublished
- 06 Moisture Content, Wood Movement and Standing and Running TrimFull sample · 70 minpublished
- 07 Wood Finishes, Stains, Finish Samples and Solid SurfacingFull sample · 70 minpublished
- 08 Fire Performance of Woodwork: Paneling, Trim and SubstratesFull sample · 75 minpublished
- 09 Accessible Millwork: Reception and Service Counters, Work Surfaces and ReachFull sample · 80 minpublished
- 10 Metals and Material Transitions in MillworkFull sample · 75 minpublished
- 11 Millwork Detailing Principles and Shop Drawing ReviewFull sample · 80 minpublished
- 12 Reception Desk and Boardroom Millwork Package (Capstone)Full sample · 90 minpublished
TDI-010 · Module 10
Construction Documentation
Describe the work clearly enough to price and to build.
Assemble a drawing set index for an interior project.
- 01 The Construction Document Set: Purpose, Legal Role and OrganizationFull sample · 80 minpublished
- 02 Sheet Sizes, Title Blocks and Sheet LayoutFull sample · 75 minpublished
- 03 Sheet Numbering and Set IndexingFull sample · 75 minpublished
- 04 Reference Systems, Symbols and NotationFull sample · 75 minpublished
- 05 General Sheets: Cover, Code Data and Life-Safety PlansFull sample · 80 minpublished
- 06 Demolition and Construction Plans: Partitions, Dimensions and TagsFull sample · 80 minpublished
- 07 Power and Data, Finish and Furniture PlansFull sample · 75 minpublished
- 08 Reflected Ceiling Plans: Content and CoordinationFull sample · 80 minpublished
- 09 Interior Elevations, Sections and DetailsFull sample · 80 minpublished
- 10 Schedules: Room Finish, Door, Hardware and MillworkFull sample · 80 minpublished
- 11 CAD Layering, BIM Coordination and Consultant DrawingsFull sample · 80 minpublished
- 12 Capstone: QA/QC Review and Issue of the SMF Construction Document SetFull sample · 85 minpublished
TDI-011 · Module 11
Specifications and Material Selection
Write requirements that a bidder can price without guessing.
Distinguish a performance specification from a proprietary product name.
- 01 The Project Manual and the Contract DocumentsFull sample · 75 minpublished
- 02 MasterFormat: Divisions and Section NumberingFull sample · 75 minpublished
- 03 SectionFormat: The Three-Part Specification SectionFull sample · 80 minpublished
- 04 Specification Methods: Proprietary, Descriptive, Performance and Reference StandardFull sample · 80 minpublished
- 05 Specification Writing Guidelines and Coordination with DrawingsFull sample · 75 minpublished
- 06 Division 01: Submittals, Substitutions and Quality RequirementsFull sample · 80 minpublished
- 07 Pricing Mechanisms in the Documents: Alternates, Unit Prices, Allowances and AddendaFull sample · 80 minpublished
- 08 Material Selection Criteria and Performance TestingFull sample · 80 minpublished
- 09 Code Performance of Interior Finishes in the SpecificationsFull sample · 80 minpublished
- 10 Specifying Floors, Walls and Ceilings for SMFFull sample · 80 minpublished
- 11 Specifying Woodwork, Doors and HardwareFull sample · 80 minpublished
- 12 Capstone: SMF Sustainability, Attic Stock, Warranties, Closeout and the Outline SpecificationFull sample · 90 minpublished
TDI-012 · Module 12
Integrated Design Case Studies
Carry one project from programme to coordinated interior documents.
Defend a coordinated decision against the original programme.
- 01 The Integrated Design Method: From Code Checklist to Coordinated DocumentsFull sample · 75 minpublished
- 02 Case Study A (Commercial Office): Occupancy, Occupant Load and EgressFull sample · 80 minpublished
- 03 Case Study A (Commercial Office): Accessibility and Partition StrategyFull sample · 80 minpublished
- 04 Case Study A (Commercial Office): Reflected Ceiling, Millwork and Detail ReviewFull sample · 80 minpublished
- 05 Case Study B (Hospitality): Boutique Hotel Restaurant Code and EgressFull sample · 80 minpublished
- 06 Case Study B (Hospitality): Finishes, FF&E Performance and SpecificationsFull sample · 80 minpublished
- 07 Case Study C (Institutional): University Learning Commons Occupancy and EgressFull sample · 80 minpublished
- 08 Case Study C (Institutional): Accessibility, Acoustics, Finishes and WayfindingFull sample · 80 minpublished
- 09 SMF Capstone 1: Code, Egress and Accessibility Verification of the Issued DesignFull sample · 80 minpublished
- 10 SMF Capstone 2: Partitions, Reflected Ceilings and Millwork CoordinationFull sample · 80 minpublished
- 11 SMF Capstone 3: Issuing the Coordinated Construction Documents and Project ManualFull sample · 75 minpublished
- 12 SMF Capstone 4: Bidding, Construction Administration, Closeout and Post-OccupancyFull sample · 85 minpublished